Date created: Friday, January 11, 2013 4:37:19 PM. Last modified: Tuesday, September 19, 2017 12:03:01 PM

SNMP with Cisco DSL

OIDs for use with Cacti or similar for tracking DSL lines on Cisco routers.



In this instance we have an 1841 with interface dialer 1 configured on an ADSL card in slot 0, as ATM0/0/0

Sync rates up and down:

snmpwalk R1 -c c0mmun1ty -v2c 1.3.6.1.2.1.10.94.1.1.3.1.5

SNMPv2-SMI::transmission.94.1.1.4.1.2.14 = Gauge32: 8064000
SNMPv2-SMI::transmission.94.1.1.4.1.2.15 = Gauge32: 8064000
SNMPv2-SMI::transmission.94.1.1.5.1.2.14 = Gauge32: 896000
SNMPv2-SMI::transmission.94.1.1.5.1.2.15 = Gauge32: 864000

ATM0/0/0 - Dialer 1 Downstream Sync:
1.3.6.1.2.1.10.94.1.1.4.1.2.14 = Gauge32: 8064000
ATM0/0/0 - Dialer 1 Upstram Sync:
1.3.6.1.2.1.10.94.1.1.5.1.2.14 = Gauge32: 896000

ATM0/1/0 - Dialer 2 Downstream Sync
1.3.6.1.2.1.10.94.1.1.4.1.2.15 = Gauge32: 8064000
ATM0/1/0 - Dialer 2 Upstream Sync:
1.3.6.1.2.1.10.94.1.1.5.1.2.15 = Gauge32: 864000

1841 sync rates when dialer 1 is configure on the DSL WIC/HWIC in slot0 as ATM0/0/0:

ATM0/1/0 - Dialer 1 Downstream Sync:
1.3.6.1.2.1.10.94.1.1.4.1.2.9 = Gauge32: 4096000
ATM0/1/0 - Dialer 1 Upstream Sync:
1.3.6.1.2.1.10.94.1.1.5.1.2.9 = Gauge32: 512000

1841 sync rates when dialer 1 is configure on the DSL WIC/HWIC in slot0 as ATM0/0/0, with interleaving enabled on the line:

ATM0/1/0 - Dialer 1 Downstream Sync (Interleave):
1.3.6.1.2.1.10.94.1.1.4.1.2.9
ATM0/1/0 - Dialer 1 Upstream Sync (Interleave):
1.3.6.1.2.1.10.94.1.1.5.1.2.9

2811 sync rates with dialer 1 configured on a WIC-1ADSL in slot0 as ATM0/0/0:

ATM0/0/0 - Dialer 1 Upstream Sync:
1.3.6.1.2.1.10.94.1.1.4.1.2.12 = Gauge32: 960000
ATM0/0/0 - Dialer 1 Downstream Sync:
1.3.6.1.2.1.10.94.1.1.5.1.2.12 = Gauge32: 8128000

1841 line stats up and down, with dialer 1 configured on ATM0/0/0 and dialer 2 on ATM0/1/0:

cpe#show dsl interface atm0/0/0 | i dB
Noise Margin:	 14.0 dB			 12.0 dB
Output Power:	 20.0 dBm			 11.0 dBm
Attenuation:	 19.5 dB			 12.0 dB
cpe#show dsl interface atm0/1/0 | i dB
Noise Margin:	 11.0 dB			 11.0 dB
Output Power:	 20.0 dBm			  9.5 dBm
Attenuation:	 18.0 dB			 10.5 dB

atm0/0/0 - Downstream Noise Margin
1.3.6.1.2.1.10.94.1.1.3.1.4.14 = Gauge32: 140
atm0/0/0 - Upstream Noise Margin
1.3.6.1.2.1.10.94.1.1.2.1.4.14 = Gauge32: 120
atm0/0/0 - Downstream Output Power
1.3.6.1.2.1.10.94.1.1.2.1.7.14 = Gauge32: 200
atm0/0/0 - Upstream Output Power
1.3.6.1.2.1.10.94.1.1.3.1.7.14 = Gauge32: 110
atm0/0/0 - Downstream Attenuation
1.3.6.1.2.1.10.94.1.1.3.1.5.14 = Gauge32: 195
atm0/0/0 - Upstream Attenuation
1.3.6.1.2.1.10.94.1.1.2.1.5.14 = Gauge32: 120

atm0/0/0 - Downstream Noise Margin
1.3.6.1.2.1.10.94.1.1.3.1.4.14 = Gauge32: 140
atm0/0/0 - Upstream Noise Margin
1.3.6.1.2.1.10.94.1.1.2.1.4.14 = Gauge32: 120
atm0/0/0 - Downstream Output Power
1.3.6.1.2.1.10.94.1.1.2.1.7.14 = Gauge32: 200
atm0/0/0 - Upstream Output Power
1.3.6.1.2.1.10.94.1.1.3.1.7.14 = Gauge32: 110
atm0/0/0 - Downstream Attenuation
1.3.6.1.2.1.10.94.1.1.3.1.5.14 = Gauge32: 195
atm0/0/0 - Upstream Attenuation
1.3.6.1.2.1.10.94.1.1.2.1.5.14 = Gauge32: 120

1841 line stats up and down, with dialer 1 configured on ATM0/0/0 with Interleave enabled on the line

atm0/0/0 - Downstream Noise Margin
1.3.6.1.2.1.10.94.1.1.3.1.4.9 = Gauge32: 200
atm0/0/0 - Upstream Noise Margin
1.3.6.1.2.1.10.94.1.1.2.1.4.9 = Gauge32: 195
atm0/0/0 - Downstream Output Power
1.3.6.1.2.1.10.94.1.1.2.1.7.9 = Gauge32: 195
atm0/0/0 - Upstream Output Power
1.3.6.1.2.1.10.94.1.1.3.1.7.9 = Gauge32: 120
atm0/0/0 - Downstream Attenuation
1.3.6.1.2.1.10.94.1.1.3.1.5.9 = Gauge32: 460
atm0/0/0 - Upstream Attenuation
1.3.6.1.2.1.10.94.1.1.2.1.5.9 = Gauge32: 260

1841 line up and down stats, with dialer 1 on ATM0/1/0

atm0/1/0 - dialer 1 - Downstream Noise Margin
1.3.6.1.2.1.10.94.1.1.3.1.4.9 = Gauge32: 115
atm0/1/0 - dialer 1 - Upstream Noise Margin
1.3.6.1.2.1.10.94.1.1.2.1.4.9 = Gauge32: 60
atm0/1/0 - dialer 1 - Downstream Output Power
1.3.6.1.2.1.10.94.1.1.2.1.7.9 = Gauge32: 200
atm0/1/0 - dialer 1 - Upstream Output Power
1.3.6.1.2.1.10.94.1.1.3.1.7.9 = Gauge32: 120
atm0/1/0 - dialer 1 - Downstream Attenuation
1.3.6.1.2.1.10.94.1.1.3.1.5.9 = Gauge32: 275
atm0/1/0 - dialer 1 - Upstream Attenuation
1.3.6.1.2.1.10.94.1.1.2.1.5.9 = Gauge32: 150

2811 line stats up and down, with dialer 1 configured on ATM0/0/

atm0/0/0 - Downstream Noise Margin
1.3.6.1.2.1.10.94.1.1.3.1.4.12 = Gauge32: 100
atm0/0/0 - Upstream Noise Margin
1.3.6.1.2.1.10.94.1.1.2.1.4.12 = Gauge32: 80
atm0/0/0 - Downstream Output Power
1.3.6.1.2.1.10.94.1.1.3.1.7.12 = Gauge32: 200
atm0/0/0 - Upstream Output Power
1.3.6.1.2.1.10.94.1.1.2.1.7.12 = Gauge32: 120
atm0/0/0 - Downstream Attenuation
1.3.6.1.2.1.10.94.1.1.3.1.5.12 = Gauge32: 180
atm0/0/0 - Upstream Attenuation
1.3.6.1.2.1.10.94.1.1.2.1.5.12 = Gauge32: 95

Previous page: SNMP Extend
Next page: SNMP with APC PDU